GB
KN6T75 SA/NLS
KN6T72 SA/NLS
Table of burner and nozzle specifications
Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of their
housing. The burner consists of two separate parts (see
pictures).
2. Unscrew the nozzles using a 7 mm socket spanner.
Replace the nozzles with models that are configured
for use with the new type of gas (see Table 1). The two
nozzles have the same hole diameter.
3. Replace all the components by completing the above
operations in reverse order.
Adjusting the burners’ primary air :
Does not require adjusting.
Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
3. Having adjusted the flame to the required low setting,
while the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the flame does not go out.
4. Some appliances have a safety device
(thermocouple) fitted. If the device fails to work
when the burners are set to the low flame setting,
increase this low flame setting using the adjusting
screw.
5. Once the adjustment has been made, replace the
seals on the by-passes using sealing wax
! If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
! Once this procedure is finished, replace the old
rating sticker with one indicating the new type of gas
used. Stickers are available from any of our Service
Centres.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in
order to comply with current national regulations).
S
R
TC A
Table 1 Natural gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
Nozzle
1/100
(mm)
Capacity*
l/h G25
Nominal Reduced
Triple.ring (TC) 130 3.10 1.50 2x99 343
Rapid (Large)
(R)
100 3.00 0.70 116 332
Semi-rapid
(Medium) (S)
75 1.90 0.40 106 210
Auxiliary
(Small) (A)
55 1.00 0.40 79 111
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
25
15
30
* At 15°C and 1013 mbar - dry gas
Natural P.C.S. = 37.78 MJ/m³