Indesit KN6T62SA(W)/I S Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
18
GB
KN6T62SA/IS
S
R
TC A
Table of burner and nozzle specifications
4. Some appliances have a safety device
(thermocouple) fitted. If the device fails to work
when the burners are set to the low flame setting,
increase this low flame setting using the adjusting
screw.
5. Once the adjustment has been made, replace the
seals on the by-passes using sealing wax
! If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
! Once this procedure is finished, replace the old
rating sticker with one indicating the new type of gas
used. Stickers are available from any of our Service
Centres.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in
order to comply with current national regulations).
Burners may be adapted for use with any type of gas
shown on the data plate, which is located inside the
flap or, after the oven compartment has been opened,
on the left-hand wall inside the oven.
TECHNICAL DATA
Oven dimensions
(HxWxD)
32x43.5x40 cm
Volume
57 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 8.5 cm
Burners
may be adapted for use with any
type of gas shown on the data plate
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Energy consumption for Natural
convection – heating mode:
Traditional mode
;
Declared energy consumption for
Forced convection Class –
heating mode:

Baking.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2004/142/EC dated 30/11/09
(Gas) 1275/2008 (Stand-by/ Off
mode)
Table 1 Liquid gas Natural gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
Bypass
1/100
(mm)
Nozzle
1/100
(mm)
Capacity*
g/h
Nozzle
1/100
(mm)
Capacity*
l/h
Nominal Reduced *** **
Triple.ring (TC) 130 3.25 1.50 63 2x65 236 232 2x99 309
Rapid (Large)
(R)
100 3.00 0.70 41 86 218 214 116 286
Semi-rapid
(Medium) (S)
75 1.90 0.40 30 70 138 136 106 181
Auxiliary
(Small) (A)
55 1.00 0.40 30 50 73 71 79 95
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 31 32

Kommentare zu diesen Handbüchern