Table of burner and nozzle specications
Table 1 Liquid Gas Natural Gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Nozzle
1/100
(mm)
Flow rate *
g/h
Flow rate*
l/h
(mm)Nomin. Reduc. G30 G31 G20
3 Rapid
100 3.00 0.7 40 86 218 214 116 286
2 Semirapid
75 1.65 0.4 30 64 120 118 96 157
1
Auxiliary
55 1.00 0.3 27 50 73 71
71 95
4 Triple Ring 130 3.25 1.3 57 91 236 232 124 309
5 Double flame (DCDR Internal) 30 0.90 0.4 30 44 65 64 74 86
5 Double flame (DCDR External) 130 4.10 1.5 63 70 298 293 110 390
Gas Oven 4.00 0.8 45 95 291 286 142 381
Supply pressure
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
Propane G31 H.s. = 50.37 MJ/Kg
Butane G30 H.s. = 49.47 MJ/Kg
Methane G20 H.s. = 37.78 MJ/m
3
CP 058 MT.2 S - CP 059 MD.3 (X) F S - CP 059 MT.2 S
TABLE OF CHARACTERISTICS
Oven
dimensions
HxLxP
32,9 x 59,5 x 39,4 cm
Volume
lt. 78
Voltage and
frequency
see data plate
Burners
may be adapted for use with any type
of gas shown on the data plate.
ENERGY
LABEL
(Electric oven)
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304-60350
Energy consumption for Natural
convection – heating mode:
Convection mode
Declared energy consumption for
Forced convection Class – heating
mode:
Fan assisted.
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent amendments.
CP 057 GT S
TABLE OF CHARACTERISTICS
Oven
dimensions
HxLxP
33 x 54 x 38 cm
Volume
lt. 68
Voltage and
frequency
see data plate
Burners
may be adapted for use with any type
of gas shown on the data plate.
This appliance conforms to the following
European Economic Community
directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EEC and subsequent
amendments.
Seitenansicht 26