2. Install the power supply cable by
loosening the cable clamp screw
and the three wire contact screws
L-N- .Connect the wires to the
corresponding terminals: the Blue wire to
the terminal marked (N), the Brown wire
to the terminal marked (L) and the Yellow/
Green wire to the terminal marked
(see diagram).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate (see table).
The appliance must be directly connected to the mains using an omnipolar
switch with a minimum contact opening of 3 mm installed between the
appliance and the mains. The switch must be suitable for the charge indicated
and must comply with current electrical regulations (the earthing wire must not
be interrupted by the switch). The supply cable must be positioned so that it
does not come into contact with temperatures higher than 50°C at any point
(the back panel of the oven, for example).
! The installer must ensure that the correct electrical connection has been
performed and that it is fully compliant with safety regulations.
Before connecting the appliance to the power supply, make sure that:
the appliance is earthed and the plug is compliant with the law.
the socket can withstand the maximum power of the appliance, which is
indicated on the data plate.
the voltage is in the range between the values indicated on the data plate.
the socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures
not be observed.
L
N
N
L
Electrical
connections
voltage:
220-240V~ 50/60Hz
(see data plate) maximum power
absorbed 2800W
APPLIANCE SPECIFICATIONS
Dimensions*
width 43,5 cm
height 32,4 cm
depth 41,5 cm
Dimensions**
width 45,5 cm
height 32,4 cm
depth 41,5 cm
Volume*
59 lt.
Volume**
62 lt.
* Only for models with drawn rails.
** Only for models with wire rails.
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments
- 2004/108/EC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2012/19/EU and subsequent
amendments.
1275/2008 standby/off mode.
Energy
Label e
Ecodesign
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
implementing Directive 2009/125/EC.
Standard EN 60350-1
Standard EN 50564
Energy consumption for Natural
convection – heating mode:
Traditional
Declared energy consumption for
Forced convection Class
mode: Baking