Installation
! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future reference.
Pass them on to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can


!
according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.
! This unit may be installed and used only in permanently
ventilated rooms in accordance with British Standard

6891 Current Editions. The following requirements must
be observed:
 
that expels any combustion fumes. This may consist of
a hood or an electric fan that automatically starts each
time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the Outside
 

must not be less than 2 m
3

The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm
2

the opening must not be vulnerable
to any type of blockages.
The system can also provide the air
needed for combustion indirectly,

air circulation tubes as described
above. However, these rooms must
not be communal rooms, bedrooms

hazard.
A
Examples of
ventilation holes
for comburant air.
Enlarging the ventilation slot
between window and floor.
Adjacent
Room
Room to be
Vented
 
than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in
the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level

being used in the room, positioned so that it is not subject


cylinder above 50°C.
Fitting the appliance
Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:
 
the top of the hob must be at least 600 mm from the edge
of the hob.
       
installation instruction manuals and at a minimum
distance of 650 mm from the hob.
 

If the hob is installed beneath a wall
cabinet, the latter must be situated
at a minimum of 700 mm above the

       

Fastening hooks are provided, allowing you to fasten
the hob to tops that are between 20 and 40 mm thick.
To ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.
555 mm
55 mm
475 mm
 
       

600mm min.
420mm min.
700mm min.