turn the tap to minimum;
remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.
check that the flame does not turn off when you turn
the tap quickly from high to low.
c) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
Burner and nozzle characteristics
S
S
R
A
K3G11/U
K3G12 /U
K3G12A/U
* At 15°C and 1013 mbar- dry gas
G30 (GPB-B) P.C.S. = 49,47 MJ/Kg
G20 (GZ50) P.C.S. = 37,78 MJ/m
3
GZ350 (GZ35) P.C.S. = 27,20 MJ/m
3
Table 1 G30 (GPB-B) G20 (GZ50) GZ350 (GZ35)
Burner Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Thermal
power
kW
(p.c.s.*)
Flow *
g/h
Thermal
power
kW
(p.c.s.*)
Injector
1/100
(mm)
Flow*
l/h
Injector
1/100
(mm)
Flow*
l/h
Reduc. Nominal Nominal
Fast (large) (R) 100 0.70 41 87 3.40 247 3.00 128 286 158 397
Semi-fast (medium) (S) 75 0.40 30 70 2.20 160 1.90 104 181 143 251
Auxiliary (Small) (A) 51 0.40 30 52 1.30 95 1.00 76 95 106 132
Supply pressure
Nom.
Min.
Max.
36
29
44
20
16
25
13
10
16