BURNER AND NOZZLE SPECIFICATIONS
* At 15°C and 1013 mbar-dry gas
Propane G31 H.s. = 50,37 MJ/kg
Butane G30 H.s. = 49,47 MJ/kg
Methane G20 H.s. = 37,78 MJ/m
3
Town gas G110 H.s. = 15.87 MJ/m³
TROUBLESHOOTING
It may occur that the appliance does not function or does not
function properly. Before calling customer services for
assistance, let's see what can be done.
First of all, check to see that there are no interruptions in the
gas and electrical supplies, and, in particular, that the gas valves
for the mains are open.
The burner does not light or the flame is not uniform
around the burner.
Check to make sure that:
The gas holes on the burner are not clogged;
All the removable parts that make up the burner are mounted
correctly;
There are no draughts around the cooking surface.
The flame does not stay on
Check to make sure that:
You press the knob all the way in;
You keep the knob pressed in long enough to activate the
safety device.
The gas holes are not clogged in the area corresponding to
the safety device.
The burner does not remain on when set to "Low".
Check to make sure that:
The gas holes are not clogged.
There are no draughts near the cooking surface.
The minimum has been adjusted correctly (see the section
entitled, "Adjusting the low flame").
The cookware is not stable.
Check to make sure that:
The bottom of the cookware is perfectly flat.
The cookware is centered correctly on the burner.
If, despite all these checks, the appliance does not function
properly and the problem persists, call the nearest Merloni Elet-
trodomestici Customer Service Centre, informing them of:
- The type of problem.
- The abbreviation used to identify the model (Mod. ...) as
indicated on the warranty.
Never call on technicians not authorised by the manufacturer,
and always refuse to accept spare parts that are not original.
OVEN TECHNICAL SPECIFICATIONS
This appliance conforms to the following European Economic
Community directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifica-
tions;
- 89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and
subsequent modifications;
- 90/336/EEC of 29/06/90 (Gas) and subsequent modifications;
- 93/68/EEC of 22/07/93 and subsequent modifications.
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection:
heating mode: Convection
Declared energy consumption for Forced
convection Class:
heating mode: Fan assisted
Table 1 Liquid gas Natural gas Town gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30/G31 G20 G110
C.
Rapid
100 3.00 0.7 40 86 218 116 286 260 680
B.
Semi-rapid
75 1.65 0.4 30 64 120 96 157 185 374
A.
Auxiliary
55 1.00 0.3 27 50 73 71 95 145 227
D.
Triple Ring
130 3.25 1.3 57 91 236 124 309 285 737
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
20
17
25
8
6
15
Seitenansicht 22