3. Reassemble the parts following the above procedure in the reverse
order.
4. Once this procedure is nished, replace the old rating sticker with
one indicating the new type of gas used. Sticker are available from
any of our Service Centres.

1. Remove the pan supports and lift the burners out of their housing.
The burner consists of two separate parts (see pictures).
2. Unscrew the nozzles using a 7 mm socket spanner. Replace the
nozzles with models that are congured for use with the new type of
gas (see Table 1). The two nozzles have the same hole diameter.
3. Replace all the components by completing the above operations in
reverse order.
Adjusting the burners’ primary air
Does not require adjusting.
Setting the burners to minimum
1. Turn the tap to the low ame position;
2. Remove the knob and adjust the
adjustment screw, which is positioned in or
next to the tap pin, until the ame is small
but steady.
3. Having adjusted the ame to the required low setting, while the burner
is alight, quickly change the position of the knob from minimum to
maximum and vice versa several times, checking that the ame does
not go out.
4. Some appliances have a safety device (thermocouple) tted. If the
device fails to work when the burners are set to the low ame setting,
increase this low ame setting using the adjusting screw.
5. Once the adjustment has been made, replace the seals on the by-
passes using sealing wax or a similar substance.
! If the appliance is connected to liquid gas, the regulation screw must
be fastened as tightly as possible.
! Once this procedure is nished, replace the old rating sticker with one
indicating the new type of gas used. Stickers are available from any of
our Service Centres.
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be tted
to the inlet pipe (in order to comply with current national regulations).
Electrical
connections
DATA PLATE
see data plate
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 43 44

Kommentare zu diesen Handbüchern

Keine Kommentare