9
Fitting on a Power Supply Cable
Opening the terminal board:
• Using a screwdriver, prise on the side tabs of the
terminal board cover;
• Pull open the cover of the terminal board.
To install the cable, proceed as follows:
• unscrew the wire clamp screw and the contact screws
Note: the jumpers are factory-set for a three-phase
400V connection (fig. D).
• to make the electrical connections illustrated in fig. F
and fig. G, use the two jumpers housed in the box (fig.
E - reference “P”)
• fasten the supply cable in place with the clamp and
close the cover of the terminal board.
Fig. D
Fig. E
Fig. F
Fig. G
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indi-
cated on the data plate. When connecting the cable di-
rectly to the mains, install an omnipolar circuit-breaker with
a minimum contact opening of 3 mm between the appli-
ance and the mains. The omnipolar circuit breaker should
be sized according to the load and should comply with
current regulations (the earth wire should not be inter-
rupted by the circuit breaker).
The supply cable should be positioned so that it does not
reach a temperature of more than 50°C with respect to
the room temperature, anywhere along its length.
Before making the connection, check that:
• The electrical safety of this appliance can only be guar-
anteed if the cooker is correctly and efficiently earthed,
in compliance with regulations on electrical safety. Al-
ways ensure that the earthing is efficient; if you have
any doubts call in a qualified technician to check the
system. The manufacturer declines all responsibility
for damage resulting from a system which has not been
earthed.
• Before plugging the appliance into the mains, check
that the specifications indicated on the date plate (on
the appliance and/or packaging) correspond to those
of the electrical mains system of your home.
BUILT-IN HOB
BUILT-IN COOKER
WHITERED
YELLOW
BLUE GREEN
Only on
certain models
NL
230V 1N~
H07RN-F 3x4 CEI-UNEL 35364
1
3
2
4
5
NL2L1
400V 2N~
H05RR-F 4x2.5 CEI-UNEL 35363
1
3
2
4
5
NL3L1L2
400V 3N~
H05RR-F 5x2.5 CEI-UNEL 35363
1
3
2
4
5