Indesit FD 61.1 (WH)/HA S Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
GB
19
Fitting the power supply cable
1. Open the terminal board by
inserting a screwdriver into the side
tabs of the cover. Use the screwdriver
as a lever by pushing it down to open
the cover (see diagram).
2. Install the power supply cable by
loosening the cable clamp screw
and the three wire contact screws
L-N- .
Connect the wires to the
corresponding terminals: the Blue
wire to the terminal marked (N), the
Brown wire to the terminal marked
(L) and the Yellow/Green wire to the
terminal marked (see diagram).
3. Secure the cable by fastening the
clamp screw.
4. Close the cover of the terminal
board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate (see table).
The appliance must be directly connected to the mains using an omnipolar
switch with a minimum contact opening of 3 mm installed between the
appliance and the mains. The switch must be suitable for the charge indicated
and must comply with current electrical regulations (the earthing wire must not
be interrupted by the switch). The supply cable must be positioned so that it
does not come into contact with temperatures higher than 50°C at any point
(the back panel of the oven, for example).
! The installer must ensure that the correct electrical connection has been
performed and that it is fully compliant with safety regulations.
Before connecting the appliance to the power supply, make sure that
The appliance is earthed and the plug is compliant with the law.
The socket can withstand the maximum power of the appliance, which is
indicated on the data plate.
The voltage is in the range between the values indicated on the data plate.
The socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures
not be observed.
N
L
Electrical
connections
voltage:
220-230V~ or 220-240V~
50/60Hz or 50Hz
(see data plate)
maximum power absorbed 2800W
ENERGY
LABEL
APPLIANCE SPECIFICATIONS
Dimensions*
width 43,5 cm
height 32,4 cm
depth 40,6 cm
Dimensions**
width 45,5 cm
height 32,4 cm
depth 40,6 cm
Volume*
58 lt.
Volume**
60 lt.
* Only for models with drawn rails.
** Only for models with wire rails.
Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304
Energy consumption for Natural
convection heating mode:
Traditional mode
Declared energy consumption for
Forced convection Class
heating mode: Baking
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments
- 2004/108/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
1275/2008 standby/off mode.