Indesit P 604 GB Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
6
Installation Instructions for built-in
The following instructions are directed at the qualified
installer so that the installation and maintenance
proceedures may be followed in the most professional and
expert manner possible.
Important: Unplug the electrical connection before
performing any maintenance or regulation upkeep
work.
Installation of built-in stove tops
The electric hobs are prepared with protection degree
against excessive heating of Y type, it is therefore possible
to instal them next to furniture which is higher than the
working board. For a correct installation of the cooking
top the following precautions must be followed:
a) The hob may be located in a kitchen, a kitonen/diner
or bed sitting room, but no in a bathroom or shower
room.
b) The hoods must be installed according to the
requirements in the hood handbook.
c) The dimensions of the cutout for the appliance must
be those indicated in the figure. Clamps are provided
to fasten the cooktop to counters measuring from 20
to 40 mm in thickness. To fasten the cooktop securely,
it is recommended that all the clamps be used.
555 mm.
55 mm.
475 mm.
Fastening Clamps - Assembly Diagram
20
30
Clamp Position for Clamp Position for
H=20mm top H=30mm top
Front
40
Clamp Position for
H=40mm top Back
N.B: Use the clamps contained in the "accessory kit."
d) In case a wooden panel should be fitted under the top
for insulation, it will have be fitted at a minimum distance
of 20 mm from the inferior part of the top.
Important: When installing the hob on a built-in oven, the
oven should be placed on two wooden strips; in the case
of a joining cabinet surface, remember to leave a space
of at least 45 x 560 mm at the back.
560 mm.
45 mm.
When installing on a built-in oven without forced ventilation,
ensure that there are air inlets and outlets for ventilating
the interior of the cabinet adequately. Assembly examples
are given in figs.
Electrical connection for electric hob
The following installation procedure must be carried out
by a qualified electrician.
Important: the cooker must be connected to the mains
by a switched (double pole) cooker outlet correctly fused
with a capacity appropriate to that shown on the hob Rating
Plate. All electrical wiring from the consumer unit to the
appliance, via the switched double pole cooker outlet, must
be of an acceptable type and current rating as above. The
supply cord, type H05 VV-F 3x2.5mm
2
, must be positioned
so that it never reaches at any point a temperature 50°C
higher than the room temperature. The electrical
installation must comply with the IEE Regulations, Building
Regulation & local By-Lays.
WARNING: THIS APPLIANCE MUST BE EARTHED.
In the case of installation over a built-in electric oven the
electrical hook-up of the stove top and that of the oven
should be separate, for reasons of safety as well as for
ease of eventual removal of the oven.
Supply cable installation
The electrcic hobs are supplied without cable. Use a cable:
H05 VV-F 3x2.5mm
2
Open the terminal box by removing the "V" screw and
taking off the cover.
The wires in the mains lead are coloured in accordance
Seitenansicht 5
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare