Electrical connection
Ovens equipped with a three-pole power supply cable are designed to operate
with alternating current at the voltage and frequency indicated on the data
plate located on the appliance (see below).
Fitting the power supply cable
1. Open the terminal board by inserting
a screwdriver into the side tabs of the
cover. Use the screwdriver as a lever
by pushing it down to open the cover
(see diagram).
2. Install the power supply cable by
loosening the cable clamp screw
and the three wire contact screws
L-N- .
Connect the wires to the corresponding
terminals: the Blue wire to the terminal
marked (N), the Brown wire to the
terminal marked (L) and the Yellow/
Green wire to the terminal marked
(see diagram).
3. Secure the cable by fastening the
clamp screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate (see table).
The appliance must be directly connected to the mains using an omnipolar
switch with a minimum contact opening of 3 mm installed between the
appliance and the mains. The switch must be suitable for the charge indicated
and must comply with current electrical regulations (the earthing wire must not
be interrupted by the switch). The supply cable must be positioned so that it
does not come into contact with temperatures higher than 50°C at any point
(the back panel of the oven, for example).
! The installer must ensure that the correct electrical connection has been
performed and that it is fully compliant with safety regulations.
Before connecting the appliance to the power supply, make sure that
The appliance is earthed and the plug is compliant with the law.
The socket can withstand the maximum power of the appliance, which is
indicated on the data plate.
The voltage is in the range between the values indicated on the data plate.
The socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures
not be observed.
L
N
N
L
APPLIANCE SPECIFICATIONS
Dimensions*
width 43.5 cm
height 41 cm
depth 41 cm
Volume*
74 l
Dimensions**
width 45.6 cm
height 41 cm
depth 41 cm
Volume**
77 l
Electrical
connections
voltage: 220-240V~ 50Hz
maximum power absorbed 3400W
(see data plate)
* Only for models with drawn rails.
** Only for models with wire rails.
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
implementing Directive 2009/125/EC.
Standard EN 60350-1
Standard EN 50564
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 2004/108/EC of 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EU and subsequent
amendments.
-
1275/2008 Stand-by/off mode
Declared energy consumption
for Forced convection Class –
heating mode:
Conventional oven
ENERGY LABEL
and
ECODESIGN
Seitenansicht 6