15
GB
Electrical connections
The cooker must be connected to the mains electricity
supply. It is designed to operate with alternating
current at the voltage and frequency indicated on the
data plate (see the following page).
The hob is connected to the cooker using a special
connector.
Fitting the power supply cable
1. Open the terminal
board by inserting a
screwdriver into the side
tabs of the cover. Use
the screwdriver as a
lever by pushing it down
to open the cover (see
diagram).
2. Install the power supply cable by loosening the
cable clamp screw and the wire contact screws L-N-
. Connect the wires to the corresponding terminals:
the Blue wire to the terminal marked (N), the Brown
wire to the terminal marked (L) and the Yellow Green
wire to the terminal marked
.
The terminal board is designed for a 400 V three-
phase connection (see diagrams below).
400V 3N~H05RR-F
5x2.5 CEI-UNEL 35363
If the electrical system has other characteristics (see
diagrams below), carry out the electrical connection
using the connection supports provided in the box P.
230V 1N~H07RN-F 3x4
CEI-UNEL 35364
400V 2N~H05RR-F
4x2.5 CEI-UNEL 35363
3. Secure the power supply cable by fastening the
clamp screw.
4. Close the cover of the terminal board.
BUILT-IN HOB
BUILT-IN COOKER
WHITE RED YELLOWBLUE GREEN
Only on
certain models
NL3L1L2
1
3
2
4
5
N
L2
L3
L1
P
NL
1
3
2
4
5
NL2L1
1
3
2
4
5
Seitenansicht 14