5. Make sure the burner does
not switch off when you turn
the knob from Max to Min
quickly, or when you open
and close the oven door
quickly.
! If the appliance is connected to liquid gas, the regulation
screw must be fastened as tightly as possible.
!
sticker with one indicating the new type of gas used. This
sticker is available from any of our Service Centres.
! If the gas pressure is different from the recommended
inlet pipe in accordance with current National Regulations.
DATA PLATE
Dimensions
width 43.5 cm
height 31 cm
depth 43.5 cm
Volume
58 l
Electrical
connections
see data plate
Gas features
see data plate
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments - 2004/108/EEC
dated 15/12/04 (Electromagnetic
compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments. 2009/142/EEC
dated 30/11/09 (Gas) and
subsequent amendments.
2012/19/EC and subsequent
amendments.
Burner and Nozzle specifications
* At 15°C and 1013,25 mbar-dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
Table
iquid ga
atural gas
Burner Thermal Power
kW (gross heat value)*
By-pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
NominalReduced (mm)
*** **
(mm)
Oven 2,60 1,00 49 78 189 186 11
48
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Electric Part
Category Thermal Power
kW (1)
Voltage frequency Power
(W)
II2H3+
2,60 (189 g/h - G30)
(186 g/h - G31)
220-230V~ 50-60Hz2250
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).