GB
17
If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Be careful of the spark plug wires and the
thermocouple tubes.
After adjusting the appliance so it may be used
with a different type of gas, replace the old rating
label with a new one that corresponds to the new
type of gas (these labels are available from
Authorised Technical Assistance Centres).
Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating
to regulators for channelled gas.
Table of burner and nozzle specifications
Table 1 Liquid gas Natural gas
Diameter
(mm)
Thermal power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
capacity*
g/h
Nozzle
1/100
capacity *
l/h
Burner
Nomin. Red. (mm) (mm) *** ** (mm)
Rapid (R) 100 3.00 0.70 41 86 218 214 116 286
Semi-rapid (S) 75 1.90 0.40 30 70 138 136 106 181
Auxiliary (A) 55 1.00 0.40 30 50 73 71 79 95
Oven - 2.60 1.00 52 78 189 186 119 248
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
TECHNICAL DATA
Oven Dimensions
HxWxD
31x43,5x43,5 cm
Volume
58 l
Useful
measurements
relating to the
oven compartment
width 46 cm
depth 42 cm
height 8,5 cm
Voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate.
EC Directives 73/23/EEC dated
19/02/73 (Low Voltage) and
subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments -
90/369/EEC dated 29/06/90 (Gas)
and subsequent amendments -
90/68/EEC dated 22/07/93 and
subsequent amendments. -
2002/96/EEC.
S
S
R
A
CG64SG1 I
Kommentare zu diesen Handbüchern