Indesit KN6I66A(X)/FR Bedienungsanleitung Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
GB
21
N
L2
L1
L3
P
NL2L1
400V 2N~
H05RR-F 4x4 CEI-UNEL 35363
1
3
2
4
5
NL3L1L2
400V 3N~
H05RR-F 5x2.5 CEI-UNEL 35363
1
3
2
4
5
Secure the power supply cable by fastening the
cable clamp screw then put the cover back on.
Connecting the supply cable to the electricity mains
Install a standardised plug corresponding to the
load indicated on the appliance data plate (
see
Technical data table
).
The appliance must be directly connected to the
mains using an omnipolar switch with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The switch must be
suitable for the charge indicated and must comply
with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply
cable must be positioned so that it does not come
into contact with temperatures higher than 50°C at
any point.
Before connecting the appliance to the power
supply, make sure that:
The appliance is earthed and the plug is compliant
with the law.
The socket can withstand the maximum power of
the appliance, which is indicated by the data
plate.
The voltage falls between the values indicated on
the data plate.
The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only.
! The manufacturer declines any liability should
these safety measures not be observed.
TECHNICAL DATA
Oven dimensions
(LxDxH)
40x43,5x32 cm
Volume 56 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 8,5 cm
Power supply
voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens. Standard EN 50304
Energy consumption for Natural
convection – heating mode:
Static
;
Energy consumption for Forced
convection – heating mode:
Baking
Mode;
EC Directives: 06/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments –
04/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments –
93/68/EEC dated 22/07/93 and
subsequent amendments –
2002/96/EC.
1275/2008 Stand-by/ Off mode
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare