If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between
this cabinet and the top
of the hob.
This distance should
be increased to 700
mm if the wall cabinets
are flammable (see figure).
Do not position blinds behind the cooker or less
than 200 mm away from its sides.
Any hoods must be installed according to the
instructions listed in the relevant operating
manual.
The cooker is fitted
with a safety chain that
must be attached to a
hook, secured to the
wall behind the
appliance.
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the places
provided on each corner of the
base of the cooker (see
figure).
The legs* fit into the slots on
the underside of the base of
the cooker.
Mounting a Power Supply Cable
Opening the terminal board:
Using a screwdriver, prise on the side tabs of the
terminal board cover;
Pull open the cover of the terminal board.
HOOD
420
Min.
min. 650 mm. with hood
min.
700 mm. without hood
mm.
600
Min. mm.
420
Min. mm.
To install the cable, proceed as follows:
Remove the wire clamp screw and the three
contact screws L-N-
Fasten the wires beneath the heads of the screws
using the following color scheme : Blue (N)
Brown (L) Yellow-Green
Fasten the supply cable in place with the clamp
and close the cover of the terminal board.
Electrical connection
Ovens with a three-pole power supply cable are
designed to operate with alternated current at the
supply frequency and voltage indicated on the data
plate (at the bottom of the oven dashboard). The
earthing conductor of the cable is the yellow-green
conductor.
Connecting the power supply cable to the mains.
Fit a normalized plug to the cable, which
corresponds to the load indicated on the data plate;
if the cooker is connected directly to the mains, an
omnipolar circuit-breaker with a minimum opening of
3 mm between the contacts, suitable for the load
indicated and complying with current directives,
must be installed between the appliance and the
mains (the earthing wire must not be interrupted by
the circuit-breaker). The power supply cable must be
positioned so that it does not exceed room
temperature by 50°C at any point of its length.
Before making the connection check that:
the limiter valve and the home system can
support appliance load (seedata plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations and the law;
there is easy access to the socket or the
omnipolar circuit-breaker once the cooker has
been installed.
Do not use reducers, adapters or shunts as these
could cause heating or burning.