6
flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.
check that the flame does not turn off when you turn the tap quickly from high to low.
c) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
On completion of the operation, replace the old rating sticker with one indicating the new type of gas used.
This sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to
fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to
“regulators for channelled gas”.
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED.
Electrical connection
Electric cookers come without a power supply cable. The cooker is designed to
operate on an electricity supply which conforms to the electrical data shown on the
Rating Plate. The cooker can be connected to the mains only after removing the back
panel of the cooker itself with a screwdriver.
N.B.: the following installation procedure must be carried out by a qualified electrician.
The electrical installation must comply with the IEE Regulations, Building & local By-
Lays.
For the installation of the feeding cable carry out the following operations:
l Using a screwdriver, prise on the side tabs of the terminal board cover
(see fig. A);
l Pull and open the junction blok lid
Important: the wires in the mains lead are coloured in accordance with the following
code:
Green & Yellow Earth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
Green & Yellow wire to terminal marked E or
or coloured Green or Green &
Yellow.
Brown wire to terminal marked L or coloured Red.
Blue wire to terminal marked “N” or coloured Black (see fig. B).
l fix the feeding cable in the special cable stop and close the cover.
N.B.: the power supply cable must have these minimum requirements:
Type: H05RR-F
Section: 3x1.5 mm
2
Ensure that the mains cable is routed away from any brackets affixed to the rear
panel and is not trapped to the rear wall when pushing the cooker into position
between cabinets.
Fig. A
4
2
N
Fig. B
L
Seitenansicht 5