interrupted by the circuit-breaker). The power supply cable
must be positioned so that it does not exceed room tem-
perature by 50°C at any point of its length. Before making
the connection check that:
the circuit breakers or fuses of the home system can
support appliance load (see data plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations and the law;
there is easy access to the socket or the omnipolar
circuit-breaker once the cooker has been installed.
N.B.: do not use reducers, adapters or shunts as these
could cause heating or burning.
Connection n° 2
Disposing of the plug.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Ensure that before disposing of the plug itself, you make
the pins unusable so that it cannot be accidentally inserted
into a socket. Instructions for connecting cable to an alter-
native plug:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow -Earth
Blue -Neutral
Brown -Live
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows.
Connect Green & Yellow wire to terminal marked E or 6
or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked L or coloured
Red. Connect Blue wire to terminal marked N or coloured
Black. If a 13 amp plug (BS 1363) is used it must be fitted
with a 13 amp fuse.
A 15 amp plug must be protected by a 15 amp fuse, either
in the plug or adaptor or at the distribution board.If you
are in any doubt about the electrical supply to your
machine, consult a qualified electrician before use.
How to connect an alternative plug
The wires in this mains lead are coloured in accordance
with the following code:
BLUE “NEUTRAL (N)
BROWN “LIVE” (L)
GREEN AND YELLOW “EARTH” (E)
Disposing of the appliance
When disposing of the appliance please remove the plug
by cutting the mains cable as close as possible to the
plug body and dispose of it as described above.
The plug and socket must be easily accessible.
Technical Specifications
Inner dimensions of the oven:
Width 43.5 cm
Depth 43.5 cm
Height 32 cm
Inner Volume of the Oven:
60 litres
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption Class certification Natural convection
heating mode: a Convection
Voltage and Frequency of Power Supply:
230-240V ~ 50/60Hz 2250W
7
This appliance conforms with the following
European Economic Community directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
- 89/336/EEC of 03/05/89 (Electromagnetic
Compatibility) and subsequent modifications;
- 93/68/EEC of 22/07/93 and subsequent
modifications.
GREEN &
YELLOW
BROWN
BLUE
13 amp fuse
CROSS-BAR
CORD GRIP