Indesit C60LCIS Bedienungsanleitung Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
30
INSTALLATION INSTRUCTIONS
SPACE FOR FIXING
The cooker can be close fitted below hotplate level. This requires a minimum distance of 600mm between cupboard
units of hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm a
bove hotplate level,
allow a side clearance of at least 65mm.
The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc.
The wall behind the cooker, 50mm below and 450mm above, and the width of
the cooker, must be a non-
combustible material such as ceramic wall tiles.
If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm
to allow the main
oven door to open fully for when removing oven shelves.
65 mm Min
840 mm Min
400 mm Min
600 mm Min
750mm Min
COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers' instructions regarding fixing height.
Seitenansicht 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare